000 | 02759nam a2200481 i 4500 | ||
---|---|---|---|
001 | 711596 | ||
005 | 20230216131748.0 | ||
007 | cr|||||||||||| | ||
008 | 190827s2019 gw a gs 000|0|eng d | ||
020 | _a9783658273521 (ebook) | ||
035 | _a(StDuBDS)AH36977100 | ||
040 |
_aStDuBDS _beng _cStDuBDS _erda _dUkPrAHLS |
||
072 | 7 |
_aMMB _2bicssc |
|
072 | 7 |
_aMMKL _2bicssc |
|
072 | 7 |
_aTDCW _2bicssc |
|
072 | 7 |
_aHEA _2ukslc |
|
072 | 7 |
_aMKA _2thema |
|
072 | 7 |
_aMKPL _2thema |
|
072 | 7 |
_aTDCW _2thema |
|
072 | 7 |
_aMKP _2thema |
|
072 | 7 |
_aMQP _2thema |
|
100 | 1 |
_aMeiser, Andreas, _eauthor. |
|
245 | 1 | 0 |
_aInhaled sedation in the intensive care unit : _ba new option and its technical prerequisites / _cAndreas Meiser. |
250 | _a1st ed. 2019. | ||
264 | 1 |
_aWiesbaden : _bSpringer, _c2019. |
|
300 |
_a50 pages : _billustrations (black and white, and colour) |
||
336 |
_atext _2rdacontent |
||
337 |
_acomputer _2rdamedia |
||
338 |
_aonline resource _2rdacarrier |
||
366 | _b20190820 | ||
520 | 8 |
_aAndreas Meiser summarizes the current literature on inhalation sedation of critically ill patients. The author discusses advantages and drawbacks of these devices in line with clinical studies demonstrating advantages of inhaled versus intravenous ICU sedation.About the Author:Dr. med. _bAndreas Meiser summarizes the current literature on inhalation sedation of critically ill patients. To meet clinical demands, he describes the development of new devices to administer volatile anesthetics together with common ICU ventilators. Their basic principle is called anesthetic reflection. The author discusses advantages and drawbacks of these devices in line with clinical studies demonstrating advantages of inhaled versus intravenous ICU sedation.About the Author:Dr. med. Andreas Meiser is working as a consultant anesthesiologist on the interdisciplinary operative ICU of the Saarland University Medical Center. He has been a pioneer in the field of inhalation ICU sedation. He has been treating patients using the AnaConDa administration devices since 2004, and has published many original articles in scientific journals on the subject. |
|
530 | _aAlso available in printed form ISBN 9783658273514 | ||
533 |
_aElectronic reproduction. _cAskews and Holts. _nMode of access: World Wide Web. |
||
650 | 7 |
_aHealth and Wellbeing _2ukslc |
|
650 | 7 |
_aAnaesthetics _2thema |
|
650 | 7 |
_aIntensive care medicine _2thema |
|
650 | 7 |
_aPharmaceutical chemistry & technology _2thema |
|
650 | 7 |
_aAccident & emergency medicine _2thema |
|
650 | 7 |
_aPharmacy / dispensing _2thema |
|
655 | 7 | _2lcsh | |
856 | 4 | 0 | _uhttp://www.vlebooks.com/vleweb/product/openreader?id=WestLondon&isbn=9783658273521 |
942 |
_n0 _2ddc |
||
999 |
_c57904 _d57904 |